ADInstruments POWER LAB Systems Available for Windows and MAC The Universal Digital Polygraph
which can manage a complete Laboratory: Isolated Organs, Cardiovascular, Spirometry, ECG, EEG,
Sport Medicine, Education, etc. etc. click here for more information |
|
DEMO CD available showing all the almost infinite
capabilities of ADI (Power Lab) Systems Ask for it, play with the real program functions and
you’ll never give up |
Perivascular and Tubing Flow meters |
|||
|
|
Simplicity, Versatility, and Accuracy Patented in 1983, Transonic Systems'
innovative ultrasonic transit-time technology has been the gold standard for
volume flow measurement for more than two decades. Measurements with
Transonic flowmeters have been independently validated in many applications
and referenced in over 3,000 publications including more than 600 publications involving rats and mice. |
|
Code T402-PP 2 Channel Flow Meter Perivascular Code T402-PT 1 Channel Perivasc. + 1 Ch. Tubing Code T402-TT 2 Channel Flow Meter Tubing |
Code T402-PB 1 Chan. Perivascular + 1 Ch. Blank Code T402-TB 1 Channel Tubing. +
1 Ch. Blank 3 Channels FlowMeters
console available |
||
TS 420
Perivascular Module Transonic
Systems' hallmark simple plug & play TS420 Flow Modules offer an
unmatched range of precision flowprobes for vessels |
|
Transit Time
Perivascular Probes Transonic
Systems probes for microcirculation with Transonic flowmeters produce
repeatable high resolution volumetric blood flow measurements on vessels as
small as 250 micron diameter, but also in vessels as large as 1000 microns..
Choosing the appropriate series, size and style probe for your application
will enhance the absolute accuracy of the flow measurement. Big size
probes available for vessels up to |
|
Perivascular Probe selection Code = MA XX Y Where
instead of “XX” you have to insert
the desired probe size in steps starting from |
|
Probes can then present
different types of reflectors and closing systems around the vessels. Easier
to let us know the purpose of your experiment (vessel to be measured, animal
used, weight of the animal, etc. and we will provide a list of suitable
probes among them you can select the most appropriate ones. |
|
TS410 Tubing
Flowmeter - In Vitro & Extracorporeal Applications Transonic
Systems' TS410 Flowmeter Module with PXL-Series sterile tubing flowsensors is
the system of choice for unparalleled volume flow measurements in tubing
applications including extracoporeal shunts and cannulas, fluid phantoms and
mock circulatory models, artificial heart and VAD performance, pulse
duplication/heart valve studies and isolated perfused organ studies. The
TS410 has: - Programmable calibration for different liquids. - Lowest
signal-to-tubing ratio ever for tubing flow measurement. - Programmable gain
for user calibration with different fluid/temperatures. - Programmable
alarms: low/high flow; received signal threshold alarm - Easy-to-read numeric
LED displays set-up/system status |
|
IN-LINE PX probes In-Line probes(PX Series) for
module TS410 are available in different sizes starting from 1,2 up to |
|
TUBING XL probes Tubing probes(XL Series) are
available in different sizes from 4 up to |
Specify Fluid (blood, water, etc.), temperature and Flow rate when
ordering In-Line or Tubing Probes |
|
TRANSONIC Laser Doppler Unit Transonic’s BLF22 Series Tissue Perfusion Monitors measure microcirculation, including
mass and velocity, for real-time assessment of perfusion. Tissue Perfusion Monitors
can be used to monitor the effects of exercise, drug treatments,
environmental or physical manipulations on target microvascular beds. A wide
range of compatible Laser Doppler Probes for acute or chronic use measure
perfusion, mass and velocity in 1 mm3 of tissue. |
|
|
Code RD CF - Constant Flow Model Code RD CP - Constant Pressure Model Code RD WK – Working Heart System Re-circulating models
available |
Langendorff Modular Systems
Isolated Heart
Perfusion The Langendorff Isolated Heart Perfusion Systems permits the researcher to create constant flow or constant Pressure or
WORKING HEART Langendorff preparations.
The system may be placed or spontaneously beating. The system can be
instrumented to measure left ventricular pressure, apical force using the
built-in pulley system and coronary resistance, as well as surface
fluorescence, luminescence and absorption. This type of system is often used for dose response studies in
pharmacology. Its compact design has been used to introduce the heart into
NMR chambers or other restricted areas. The heart chamber, components, and
perfusate lines are water-jacketed for temperature control. The system is color coded for easy assembly and features charts with
basic protocols and instructions. Recommended when measurements of actual cardiac work or cardiac
efficiency are necessary, such as in metabolic or transgenic studies. Accessories: ED 13 – Heating
and Circulating Bath MX - Dual Channel Peristaltic Pumps Electro
Stimulators and electrodes |
|
-
Ideal for teaching, doing
its simplicity to be cleaned and handled
-
Mounted on a Perspex chassis
with two fixing holes, where the stand is located -
It can be mounted, side by
side, as many units as necessary. Standard stand: up to 6 units. -
A water thermoregulated
pump (not included) must to be used to heat the organ bath. • This pump is able to heat up to six units. -
Three -way Teflon key for
filling & emptying Code LE 11-100 One chamber with
Thermoregulator Code LE 11-200 Two chambers with
Thermoregulator Code LE 11-400 Four chambers with
Thermoregulator |
Compact series Isolated Organ Bath The main perspex reservoir
houses the heater system, the chambers and coils, all submerged in
thermostatetically controlled water. The water heating is controlled by an
external unit, supplied with each system.
Two basic models: A - Manual Emptying & Filling
System through a 3-way teflon key :
Code LE 01.00X (X = 2, 4, 6 or 8
chambers) B - Automatic Emptying & Filling System through electrovalves
operated manually by keys or remote controlled by a PC or Programmer: -
Assembly on the front side
(space saving) -
Chambers & Coils
removable by pressure (totally interchangeable and easy to clean) -
Individual air bubbling
with high precision regulation through a porous diffuser -
Possibility of working by overflowing
or by total emptying of the chamber -
Proportional heating
gradient of the heater system: avoids thermal inertia |
-
Heated water circulation
without turbulence -
Security water level sensor -
Additional air outlet for
the external tissue reservoir -
Inflow of the
physiological salt solution is done through rear connectors for each coil
separately: allows the use of different solutions in each chamber |
To
view ELECTRIC STIMULATORS click
here
HEATING
BATH Internal/External
Circulation A wide range of Int/Ext.
Circulation heating baths for any demands, also available with refrigeration.
Digital thermostat adjustment
with resolution in steps of 0.1°C, capacity from Code ED5
Capac. 5
lt. Range 20- Code EH13 Capac 13 lt. Range 20- Code EH19 Capac. 19 lt. Ran. 20- A wide range of models available |
|
|
Refrigerating
Bath –Cryostat with Internal/External circulation A wide range of Cryostat
Bath reaching up to Code F12ED Capac. 4,5 lt.
Range -20 + Code F34EH Capac. 20 lt. Range -25
+ Code FP40MC Capac. 16 lt. Range -40
+ Code FP50HL Capac. 8 lt. Range -50 + Code 8 940 114 Special additive liquid for low temperature
operation up to Code 8 940 106 Special additive liquid for low temperature
operation up to |
|
Heating
Immersion Circulators, Bridge Mounted Circulator Open Heating Bath
Circulators, Heating Circulators with Open Bath Refrigerated/Heating
Circulators - High Temperature Circulators Cryo-Compact Circulators - Ultra-Low
Refrigerated Circulators A
wide range of Baths are available Ask
for for a dedicated quote according to your needs |
TRANSDUCERS
Code FORT 25 High Sensitivity Isometric Force Transducer
10 mg – Code FORT 100 Isometric Force Transducer 1 – Code DSPL Isotonic Transducer for displacement
recording Code CELS Temperature Probe Code LUME Light Transducer (photo-meer) Blood Pressure click here: BP Transducers |
Code PNEU01 Differential Pressure Transducer. 1 psig. Code PNEU05 Differential Pressure Transducer. 5 psig. Code PNEU15 Differential Pressure Transducer. 15 psig. |
|
HIgh
Sensitivity Isometric Force Transducer
A
single transducer for a wide range of forces starting from just a few mg up
to Code FORT 25 High Sensitivity Isometric Force Transducer
10 mg – |
Isotonic Displacement Transducer
The
Isotonic Transducer measures displacements with pre-adjusted loads (position
transducer). Code TRO 015 Isotonic Displacement Transducer |
|
Examination of small Vessel/Arteries with
diameters ranging from 60 micron to around High resolution transducers and amplifiers:
Force resolution 0,01 mN. Analog output for Chart Recording or DATA
Acquisition System Code 310-A Single Wire Myograph System Code
410-A Dual
Wire Myograph System Code
510-A Auto
Dual Wire Myograph System Code
610-M Multi
Wire Myograph System System Code
120-CW
Confocal Single Wire Myograph Code
120-CP Pressure Myograph System |
|
Pressure Myograph System - 111P The
Pressure Myograph is for studying pressure-diameter relations of cannulated
small arteries (diameter >50µm), which can be seen through an inverted
microscope. Video measurements are done of external and internal diameters
through a window in the base of the Myograph with continuous display of
microscope image, vessel dimensions, flow, force and temperature on monitor.
Transducers continuously monitoring inflow and outflow pressures and longitudinal
tension to allow standardization of arterial length using micrometer. Confocal Pressure Myograph System - 120CP The
confocal pressure myograph is a system specifically for use with laser
scanning confocal microscopes (LSCM) and used to study intracellular ion activity
and isobaric constriction of isolated sections of small resistance arteries
(diameter >50µm). |
|
DMT Myograph Systems DMT A/S develops and produces equipments for customers
with the field of cardiovascular research in both the public and private
sector. The equipment is used primarily for pharmacological and physiological
studies of arteries and veins. Danish Myo Technology A/S (former J.P.
Trading) is a medical- and biotechnology company with more than twenty years
of experience in the development and manufacture of myograph equipment
designed for the in vitro assessment of vascular structure and function.
Historically, myography development closely mirrors the scientific
discoveries of the 1980s and 1990s when the basic mechanisms underlying the
development of vascular changes in hypertension, diabetes and atherosclerosis
were elucidated. Basing our designs and techniques on the methodologies of
Professor M. J. Mulvany (Inst. of Pharmacology, University of Aarhus,
Denmark), we have integrated the needs of the user with first class
mechanical, electronical and software engineering to become one of the worlds
leading designers and manufactures of wire, pressure and perfusion myographs.
- Examination of small Vessel/Arteries
with diameters ranging from 60 micron to around - Code 310-A Single Wire Myograph System -
Code 410-A Dual Wire Myograph System -
Code 510-A Auto Dual Wire Myograph System -
Code 610-M Multi Wire Myograph System
System -
Code 120-CW Confocal Single Wire Myograph -
Code 120-CP
Pressure Myograph System |
Pressure Myograph for Rapid Freezing - 115FP This pressure myograph chamber is designed
for biochemical or morphological studies where rapid freezing of the vessel
is frequently required. This chamber is ideal for rapid freezing of a
cannulated and pressurized vessel for biochemical studies, or for quick
transfer from a physiological solution into a fixative for morphological
studies. The experimental chamber is made of stainless steel. A window at the
base of the chamber allows the vessel dimensions to be digitized for analysis
of diameter etc. The adjoining chamber, which is removable, is used for
freezing or adding other fixing solutions. By raising the segment holder and
thus the vessel and its tubing, the chamber stage can be moved to the side,
for rapid or instant freezing or removing of the vessel segment for later
analysis. This process can be done in less than a second. This chamber can be
obtained as a complete setup - similiar the 110P, or as an add-on to the 110P |
|
Pressure Myograph System - 111P The Pressure Myograph is for studying pressure-diameter relations of cannulated small arteries (diameter >50µm), which can be seen through an inverted microscope. Video measurements are done of external and internal diameters through a window in the base of the Myograph with continuous display of microscope image, vessel dimensions, flow, force and temperature on monitor. Transducers continuously monitoring inflow and outflow pressures and longitudinal tension to allow standardization of arterial length using micrometer. Intravascular pressures controlled by an easily adjustable turret with optional servo control. A heating system gives electronic feedback for maintaining organ chamber temperature above ambient temperature. The chamber cover includes ports for superfusion, for rapid draining and filling, and for gas supply. All measurements are continuously recorded by the computer. |
Custom
Made Glass Hardware
Our Glass Laboratory can manufacture any kind of Glass Hardware according to customers’ own whishes: -
Chambers of any volume and
dimensions -
Oxygenating Bubblers with
porous frit -
Pre-warming coils -
Electrode and Tissue
Supports Ask for more information
|
|
|
TISSUE
SUPPORT and TISSUE MOUNTING CLIPS
Code
158815-6
Tissue Support Transducer Wire 6" Long pkg of4 Code
158816
L-Shape Tissue Support for Baths
Pkg of 6 (specify chamber volume) Code 158817 Tri-Shape Tissue Support for 5-10cc
Baths Pkg of 12 Code 158801 Tissue Clips/Two tips meeting 8 x Code 158802 Tissue Clips/Two flat surfaces 6 x |
|
InVivo Manual Gravity Perfusion Systems Steady gravity-fed delivery of buffer and fixative results in complete
perfusion. Consistent results - Steady
gravity-fed delivery of buffer and fixative results in complete perfusion. Easy to setup, use and clean - Complete
system with everything down to the needles. Fits in standard hoods. "I can perfuse up to five
animals an hour, plus it costs no more than a tube of enzyme." Code IV-140
InVivo Perfusion System 140ml – Mouse Code IV-800
InVivo Perfusion System 800ml - Rat Code IV-4140 Double
InVivo Perfusion System 4x 140ml - Double Mouse |
|
via L. Da Vinci
tel. +39 0332 773210 Fax +39 0332 970141