Data Acquisition
System Available for Windows and MAC |
|
|
|
16 INPUT channels Real Time analyses and graphics Virtual Channels for signal derivation USB or Ethernet (LAN) connection The AcqKnowledge software
included with each MP System is an interactive, intuitive program that lets
you instantly view, measure, analyze and transform data. Perform complex data
acquisition, triggering and analyses using simple pull-down menus and
dialogs--no need to learn a programming language or new protocol.
On Line calculation of a wide
range of parameters (Heart Rate, systolic, diastolic, average, filters,
histogram, peaks, integral, |
MP Systems: Sophisticated solutions for data acquisition and analysis User Friendly, No programming language required, just a
click on the mouse The
MP System hardware provides a flexible tool for your research and teaching
needs. The modular, powerful interface system can be used with BIOPAC
amplifiers and accessories and with equipment you already have. The
newly expanded range of amplifiers further enhances your ability to create a
system to suit your application requirements. Amplifiers snap together and
pull apart for simple substitutions. MP
Starter Systems include all hardware, software and documentation you need to
get started…then you can add amplifier modules, transducers, and electrodes
to match your research design. |
|
|
|
Bridge Amplifier (Isometric, Isotonic, Blood Pressure Transducers) ECG Cardiac Output EEG ERS EMG Respiration Pneumogram O2 & CO2 Module Photo Plethysmogram Goniometers Stimulator Non Invasive BP |
|
|
Evoked Response Pulse Oxymeter |
||
|
DEMO CD available showing all the almost infinite capabilities
of MP BIOPAC Systems Ask for it, play with the real program functions and
you’ll never give up |
||
|
Perivascular and Tubing Flow meters |
|||
|
|
Simplicity, Versatility, and Accuracy Patented in 1983, Transonic Systems'
innovative ultrasonic transit-time technology has been the gold standard for
volume flow measurement for more than two decades. Measurements with
Transonic flowmeters have been independently validated in many applications
and referenced in over 3,000 publications including more than 600 publications involving rats and mice. |
|
|
Code T402-PP 2 Channel Flow Meter Perivascular Code T402-PT 1 Channel Perivasc. + 1 Ch. Tubing Code T402-TT 2 Channel Flow Meter Tubing |
Code T402-PB 1 Chan. Perivascular + 1 Ch. Blank Code T402-TB 1 Channel Tubing. +
1 Ch. Blank 3 Channels
FlowMeters console available |
||
|
TS 420
Perivascular Module Transonic
Systems' hallmark simple plug & play TS420 Flow Modules offer an
unmatched range of precision flowprobes for vessels 0.25 mm and larger; a spectrum
of applications including cardiac output and cardiovascular dynamics, renal
hypertension, carotid thrombosis and stroke models, hemorrhagic shock,
ischemia/reperfusion, portal hypertension, and hindlimb studies. - Accurately
measures volume flow of less than 1 ml/min - Expanded ultrasonic frequency
range for the smallest flowprobes imaginable! Implantable 0.5 mm and 0.7 mm mouse
probes. - 160 Hz bandwidth to accurately
characterize flow dynamics at high mouse heart rates - Analog meter displays
voltage proportional to flow. - Easy access front panel receptable for
chronic probe calibration keys |
|
|
Transit Time
Perivascular Probes Transonic
Systems probes for microcirculation with Transonic flowmeters produce
repeatable high resolution volumetric blood flow measurements on vessels as
small as 250 micron diameter, but also in vessels as large as 1000 microns..
Choosing the appropriate series, size and style probe for your application
will enhance the absolute accuracy of the flow measurement. Big size
probes available for vessels up to 20 mm. |
|
|
|
Perivascular Probe selection Code = MA XX Y Where
instead of “XX” you have to insert
the desired probe size in steps starting from 0,25 mm diameter up to 20
mm. Instead of “Y” you have to insert the selectedcable exit type where B = Back or S = side (lateral) |
|
|
Probes can then present
different types of reflectors and closing systems around the vessels. Easier
to let us know the purpose of your experiment (vessel to be measured, animal
used, weight of the animal, etc. and we will provide a list of suitable probes
among them you can select the most appropriate ones. |
||
|
|
TS410 Tubing
Flowmeter - In Vitro & Extracorporeal Applications Transonic
Systems' TS410 Flowmeter Module with PXL-Series sterile tubing flowsensors is
the system of choice for unparalleled volume flow measurements in tubing
applications including extracoporeal shunts and cannulas, fluid phantoms and
mock circulatory models, artificial heart and VAD performance, pulse
duplication/heart valve studies and isolated perfused organ studies. The
TS410 has: - Programmable calibration for different liquids. - Lowest
signal-to-tubing ratio ever for tubing flow measurement. - Programmable gain
for user calibration with different fluid/temperatures. - Programmable
alarms: low/high flow; received signal threshold alarm - Easy-to-read numeric
LED displays set-up/system status |
|
|
IN-LINE PX probes In-Line probes(PX Series) for
module TS410 are available in different sizes starting from 1,2 up to 25 mm diameter . |
|
TUBING XL probes Tubing probes(XL Series) are
available in different sizes from 4 up to 25 mm according to the
tube which has to be used. |
|
Specify Fluid (blood, water, etc.), temperature and Flow rate when
ordering In-Line or Tubing Probes |
|
|
|
TRANSONIC BLF Laser Doppler Unit Transonic Systems' BLF 21-Series
perfusion monitors measure microcirculation in 1 cubic mm of tissue for
real-time assessment of perfusion in patients. Flowmeters monitor the effects
of excercise, drug treatments, environmental or physical manipulations on
target microvascular beds. Dual channel units can monitor an experimental
tissue along with a control or a second area of affected tissue. Two basic
styles of Laser Doppler Probes are available: those for acute use and the
chronic application probe. Continuous measurements can be taken in skin with
surface probes: intraopertively in organs with surface, straight or needle
probes: and internally with endoscopic probes. The mono-fiber probe can be
used to measure perfusion with fibers inplanted in tissue of lab animals. |
- BLF 21 – Single Ch.
Laser Unit - BLF21D- Dual Channel
Unit - Needle probes from 11 to
24 Gauge - Surface probes from 6 up
to 14 mm |
|
|
|
|
- Needle Probes 0,5 and 1
mm diameter - Surface probes from 5 to 15 mm in diameter |
BIOPAC Laser Doppler
Amplifier and Probes (MP100 Biopac Unit Required) BIOPAC LDF100C is a laser Doppler tissue
perfusion monitor for measuring micro-vascular blood flow in tissue.
The LDF100C module delivers a low power beam of laser light down an optical
fiber to the tissue being studied; typically, the volume of tissue sampled by
the light is in the order of 1mm3. The LDF100C module analyzes the Doppler
shift created by moving red blood cells and outputs a channel indicating
blood flow expressed in Blood Perfusion Units (BPU). On a second channel the
LDF100C simultaneously outputs the tissue remittance (Backscatter) from 0 to
100%. Up to four LDF100C modules can be used with a single MP System. The
TSD140 series surface probes are designed for skin and exposed tissue
blood flow monitoring. All surface probes are made from black Delrin®. The
signal delivery fiber intersects the probe body at a right angle, making the
probes easy to secure to the skin or tissue surface. The
TSD140 series needle probes are designed for invasive and endoscopic
blood flow monitoring of tissue. The signal delivery fiber terminates
straight into the top of the needle, making the probes easy to insert into
tissue. |
|
Optic Fiber probes available for both
Transonic and Biopac Laser Doppler Flow-Meter Units All the Flow-Meters Units can be
connected to PC via the BIOPAC Software (see correspond. section) |
|
|
Code RD CF - Constant Flow Model Code RD CP - Constant Pressure Model Code RD WK – Working Heart System Re-circulating models
available |
Langendorff Modular Systems
Isolated Heart
Perfusion The Langendorff Isolated Heart Perfusion Systems permits the researcher to create constant flow or constant Pressure or
WORKING HEART Langendorff
preparations. The system may be placed or spontaneously beating. The system can
be instrumented to measure left ventricular pressure, apical force using the built-in
pulley system and coronary resistance, as well as surface fluorescence,
luminescence and absorption. This type of system is often used for dose response studies in
pharmacology. Its compact design has been used to introduce the heart into
NMR chambers or other restricted areas. The heart chamber, components, and
perfusate lines are water-jacketed for temperature control. The system is color coded for easy assembly and features charts with
basic protocols and instructions. Recommended when measurements of actual cardiac work or cardiac
efficiency are necessary, such as in metabolic or transgenic studies. Accessories: ED 13 – Heating
and Circulating Bath MX - Dual Channel Peristaltic Pumps Electro
Stimulators and electrodes |
|
|
-
Ideal for teaching, doing its simplicity to
be cleaned and handled -
Mounted on a Perspex chassis with two fixing
holes, where the stand is located -
It can be mounted, side by side, as many
units as necessary. Standard stand: up to 6 units. -
A water thermoregulated pump (not included)
must to be used to heat the organ bath. •
This pump is able to heat up to six units. -
Three -way Teflon key for filling &
emptying Code LE 11-100 One chamber with
Thermoregulator Code LE 11-200 Two chambers with
Thermoregulator Code LE 11-400 Four chambers with
Thermoregulator |
|
Compact series Isolated Organ Bath The main perspex reservoir
houses the heater system, the chambers and coils, all submerged in
thermostatetically controlled water. The water heating is controlled by an
external unit, supplied with each system.
Two basic models: A - Manual Emptying &
Filling System through a 3-way teflon key :
Code LE 01.00X (X = 2, 4, 6 or 8
chambers) B - Automatic Emptying & Filling System through electrovalves
operated manually by keys or remote controlled by a PC or Programmer: -
Assembly on the front side (space saving) -
Chambers & Coils removable by pressure
(totally interchangeable and easy to clean) -
Individual air bubbling with high precision
regulation through a porous diffuser -
Possibility of working by overflowing or by
total emptying of the chamber -
Proportional heating gradient of the heater
system: avoids thermal inertia |
-
Heated water circulation without turbulence -
Security water level sensor -
Additional air outlet for the external tissue
reservoir -
Inflow of the physiological salt solution is
done through rear connectors for each coil separately: allows the use of
different solutions in each chamber |
To
view ELECTRIC STIMULATORS click
here
|
HEATING
BATH Internal/External
Circulation A wide range of Int/Ext.
Circulation heating baths for any demands, also available with refrigeration.
Digital thermostat
adjustment with resolution in steps of 0.1°C, capacity from 2 liters up to 25
liters, heating power from 500 W up to 3000W. Code ED5
Capac. 5
lt. Range 20-100°C Pump 15 l/min Code EH13 Capac 13 lt. Range
20-150°C Pump 15 l/min Code EH19 Capac. 19 lt. Ran.
20-150°C Pump 15 l/min A wide range of models available |
|
|
|
Refrigerating
Bath –Cryostat with Internal/External circulation A wide range of Cryostat
Bath reaching up to 50 °C below zero. Powerful circulating pump for external
requirements. Code F12ED Capac. 4,5 lt.
Range -20 +100°C Pump 15 l/min (for
temperature below 0°C use special additive t) Code F34EH Capac. 20 lt. Range -25
+150°C Pump 15 l/min (for temperature
below 0°C use special additive) Code FP40MC Capac. 16 lt. Range -40
+200°C Pump 15 l/min (for temperature
below 0°C use special additive) Code FP50HL Capac. 8 lt. Range -50
+200°C Pump 15 l/min (for temperature
below 0°C use special additive) Code 8 940 114 Special additive liquid for low
temperature operation up to 20°C
below zero (bottle of 10 liters) Code 8 940 106 Special additive liquid for low
temperature operation up to 40°C
below zero (bottle of 10 liters) |
|
|
Heating
Immersion Circulators, Bridge Mounted Circulator Open Heating Bath
Circulators, Heating Circulators with Open Bath Refrigerated/Heating
Circulators - High Temperature Circulators Cryo-Compact Circulators - Ultra-Low
Refrigerated Circulators A
wide range of Baths are available Ask
for for a dedicated quote according to your needs |
TRANSDUCERS
Code FORT 25 High Sensitivity Isometric Force Transducer
10 mg – 25 g Range Code FORT 100 Isometric Force Transducer 1 – 100 gram Range Code DSPL Isotonic Transducer for displacement
recording Code CELS Temperature Probe Code LUME Light Transducer (photo-meer) Blood Pressure click here: BP Transducers |
Code PNEU01 Differential Pressure Transducer. 1 psig. Code PNEU05 Differential Pressure Transducer. 5 psig. Code PNEU15 Differential Pressure Transducer. 15 psig. |
|
|
HIgh
Sensitivity Isometric Force Transducer
A
single transducer for a wide range of forces starting from just a few mg up to
25 grams. High sensitivity for small tissue such as aorta rings up to muscle
of develop a force of 10 or 20 grams. Code FORT 25 High Sensitivity Isometric Force Transducer
10 mg – 25 g Range |
Isotonic Displacement Transducer
The
Isotonic Transducer measures displacements with pre-adjusted loads (position
transducer). Code TRO 015 Isotonic Displacement Transducer |
|
|
Examination of small Vessel/Arteries with
diameters ranging from 60 micron to around 3 mm. High resolution transducers and amplifiers:
Force resolution 0,01 mN. Analog output for Chart Recording or DATA
Acquisition System Code 310-A Single Wire Myograph System Code
410-A Dual
Wire Myograph System Code
510-A Auto
Dual Wire Myograph System Code
610-M
Multi Wire Myograph System System Code
120-CW
Confocal Single Wire Myograph Code
120-CP Pressure Myograph System |
|
|
Pressure Myograph System - 111P The
Pressure Myograph is for studying pressure-diameter relations of cannulated
small arteries (diameter >50µm), which can be seen through an inverted
microscope. Video measurements are done of external and internal diameters through
a window in the base of the Myograph with continuous display of microscope
image, vessel dimensions, flow, force and temperature on monitor. Transducers
continuously monitoring
inflow and outflow pressures and longitudinal
tension to allow standardization of arterial length using micrometer. Confocal Pressure Myograph System - 120CP The
confocal pressure myograph is a system specifically for use with laser
scanning confocal microscopes (LSCM) and used to study intracellular ion activity
and isobaric constriction of isolated sections of small resistance arteries
(diameter >50µm). |
|
|
|
DMT Myograph Systems DMT A/S develops and produces equipments for customers
with the field of cardiovascular research in both the public and private
sector. The equipment is used primarily for pharmacological and physiological
studies of arteries and veins. Danish Myo Technology A/S (former J.P.
Trading) is a medical- and biotechnology company with more than twenty years
of experience in the development and manufacture of myograph equipment
designed for the in vitro assessment of vascular structure and function.
Historically, myography development closely mirrors the scientific
discoveries of the 1980s and 1990s when the basic mechanisms underlying the
development of vascular changes in hypertension, diabetes and atherosclerosis
were elucidated. Basing our designs and techniques on the methodologies of
Professor M. J. Mulvany (Inst. of Pharmacology, University of Aarhus,
Denmark), we have integrated the needs of the user with first class
mechanical, electronical and software engineering to become one of the worlds
leading designers and manufactures of wire, pressure and perfusion myographs.
- Examination of small
Vessel/Arteries with diameters ranging from 60 micron to around 3 mm. High
resolution transducers and amplifiers: Force resolution 0,01 mN. Analog
output for Chart Recording or DATA Acquisition System -
Code 310-A Single Wire Myograph System -
Code 410-A Dual Wire Myograph System -
Code 510-A Auto Dual Wire Myograph
System -
Code 610-M Multi Wire Myograph System
System -
Code 120-CW Confocal Single Wire Myograph -
Code
120-CP Pressure
Myograph System |
|
Pressure Myograph for Rapid Freezing - 115FP This pressure myograph chamber is designed
for biochemical or morphological studies where rapid freezing of the vessel
is frequently required. This chamber is ideal for rapid freezing of a
cannulated and pressurized vessel for biochemical studies, or for quick
transfer from a physiological solution into a fixative for morphological
studies. The experimental chamber is made of stainless steel. A window at the
base of the chamber allows the vessel dimensions to be digitized for analysis
of diameter etc. The adjoining chamber, which is removable, is used for
freezing or adding other fixing solutions. By raising the segment holder and
thus the vessel and its tubing, the chamber stage can be moved to the side,
for rapid or instant freezing or removing of the vessel segment for later
analysis. This process can be done in less than a second. This chamber can be
obtained as a complete setup - similiar the 110P, or as an add-on to the 110P |
|
|
|
Pressure Myograph System - 111P The Pressure Myograph is for studying
pressure-diameter relations of cannulated small arteries (diameter >50µm),
which can be seen through an inverted microscope. Video measurements are done
of external and internal diameters through a window in the base of the
Myograph with continuous display of microscope image, vessel dimensions,
flow, force and temperature on monitor. Transducers continuously monitoring
inflow and outflow pressures and longitudinal tension to allow standardization
of arterial length using micrometer. Intravascular pressures controlled by an
easily adjustable turret with optional servo control. A heating system gives
electronic feedback for maintaining organ chamber temperature above ambient
temperature. The chamber cover includes ports for superfusion, for rapid
draining and filling, and for gas supply. All measurements are continuously
recorded by the computer. |