Code 51600 Lab Standard Stereotaxic Unit Code 51603 Dual Arm Stereotaxic Unit |
Lab Standard Stereotaxic
Affordably
priced...immediate delivery - The 51600 Lab Standard™ Stereotaxic Instrument is ideal for researchers in need of a
versatile, reliable instrument for stereotaxic procedures with small animals.
Precision alignment when using the Lab Standard™ ensures accurate placement
of electrodes, micropipettes, and other devices. Easily Read
Scales - All scales
are oriented to be read easily from the open end of the ‘U’. This is the
position from which most scientists prefer to work. The numerals on the
scales are larger, and therefore more easily read. The scale lines are laser
engraved, to allow finest possible permanent marking of scales on all 3 axes.
Precise alignment with facing vernier scales gives accurate resolution to
0.1mm. Smooth Movements - The Lab Standard’s™ exclusive, triple lead screws
allow the fastest positioning possible, consistent with lining up the scales
easily at a given coordinate. Versatility of Positioning. The manipulator arm controls medio-lateral and vertical positioning
via lead screws, and antero-posterior movement via dovetail slide movement,
with 80 mm of travel possible in each direction. A Universal Joint allows the
investigator to change the angle of the probe up to 90o in either the
antero-posterior or medio-lateral planes. The improved locking mechanism on
the Lab Standard™ will hold any angle position without slippage. And of
course, it also provides an absolute lock at 90o vertical.
51603 two vertical arms and probe holders available.
|
Mouse Adaptor
The 51624 Mouse Adaptor holds the mouse head by means of a palate bar
and nose clamp, without ear bars. (Ear bars can cause breathing difficulties and
bleeding in mice.) Head angle may be adjusted to achieve skull flat or other
approach angles. Fits 51600 and 51800 series stereotaxic instruments.
Code
51624 Mouse Adpator |
|
Cunningham™ Mouse and Neonatal Rat
Adaptor
The Cunningham™
Mouse and Neonatal Rat Adaptor employs light, Delrin® ear bars with tapered
points on one end, and rubber pads on the other, to facilitate surgery on
mice and rat pups Unique, light ear bars - Ear bars may be independently
adjusted in height, a unique feature of this stereotaxic instrument, to level
the skull. Laser engraved scales show the vertical positions of the ear bars.
A tooth bar and nose clamp secures the nose. A well, carved in the thick
aluminum body, may be filled with dry ice and alcohol for hypothermic
anesthesia of neonatal animals. The 51625 Adaptor clamps securely on the
right side of the "U" frame of the Lab Standard™. Model organisms with soft skulls, such as
the mouse and the neonatal rat, are difficult to secure firmly in a
traditional stereotaxic instrument. The stainless steel ear bars used for
adult rats are too heavy to provide a secure hold without compressing the
sides of the skull inward (which closes the airways and impedes blood flow.)
Further, the neonatal rat pup has no external opening of the auditory canal
into which to insert the ear bar points. |
Code 51625 Cunningham
Mouse and Neonatal Rat Adaptor |
|
|
|
|
|
|
Large Probe Holders support shafts with diameters
from 6.5 mm up to 13 mm. This will hold Hamilton™ Micro-syringes or Micro
Drills. Code
51633 Large Probe
Hold. |
The Gas Anesthesia Platform for Mice allows
for precise and secure positioning of an animal during anesthesia and surgery
when used with Mouse and Neonatal Rat Adaptor ( 51625) N. 50264 Anestesia Platfform |
Holds 3.4 mm cannula heads, as manufactured
by Plastics One™ for cannula sets, and DURECT for ALZET® Osmotic Pumps.
Non-intrusive for cementing cannulas in place. Code
51636 Cannula Holder |
The CunninghamTM Spinal Adaptor is an
accessory to be mounted on the 51600 or other brands of stereotaxic instruments,
converting them for spinal surgery applications. Code 51690 Spinal Adaptor |
|
|
GAS ANESTHESIA MASKS for STEREOTAXIC
These Adapter Masks enable the Scientist
to use Gas Anesthesia on Rats and
Mice on most common Stereotaxic Instruments without personal exposure to the
gas. Available in two different sizes for Rats and Mice Code
51610 Gas
Anesthesia Mask for Rats Code
51609 Gas
Anesthesia Mask for Mice |
Digital Lab Standard™ Stereotaxic
We have added a sealed electronic sensor, highly immune to outside
interference and environmental conditions, to each axis of the manipulator
arm. Measurements are accurate to 10 microns in all three directions.
Movements in all three directions are now monitored by a large, easy-to-read
LED display module, with a resolution selectable from 1 mm to 10 microns.
A zeroing function allows the user to set a reference point for targeting
specific coordinates on the animal’s skull for injection, implantation, etc.
Calculation of distance measurements via the vernier scales is thus no longer
necessary…saving the user valuable time and improving accuracy.
Code 51900 Digital Lab Standard Stereotaxic
Unit 45 or 18 degrees EAR BARS available |
|
|
Code 51725 Just x mice Manual Unit Code 51725D Just x mice DIGITAL |
Just for Mice Dual™
Stereotaxic Unit Two Stereotaxics on a single base -
Accurate to 10 microns (Digital Only) - Delrin® ear bars, including
independent adjustment in height -
Triple lead screw for fast positioning - Also ideal for neonatal rats and
other small rodents. The Just For Mice™ Stereotaxic Instrument was specifically
developed for the expanding growth of research being conducted in
laboratories using knock-out and transgenic mice. The Just For Mice™ is ideal
for researchers in need of a versatile, reliable instrument for stereotaxic
procedures with mice and other small rodents. This innovative instrument
allows the user to perform surgical procedures on two mice at one time.
Precision alignment when using the Just For Mice™ ensures accurate placement
of electrodes, micropipettes, cannula, and other devices. Waiting time can be virtually eliminated.
For example, in applications that require drying time for cranial plaster,
surgery can be performed on one mouse while the cranial cement is drying on
the other mouse. We have created two stereotaxic instruments on a single
base. The base is 10” x 17” and has two ear bar slots located on each side. A
tooth bar and nose clamp secures the nose. A single manipulator arm controls
medio-lateral and vertical positioning
via lead screws, and
antero-posterior movement
via dovetail slide movement, with |
|
80mm of travel possible in each
direction, allowing access to both ear bar locations. Unique, light ear
bars Ear bars may be independently adjusted in height – a unique feature
of this stereotaxic instrument – to level the skull. Ear bars are composed of
light Delrin® material with tapered points or non-invasive rubber pads or jaw
holder cuffs. |
|
|
Motorized Lab Standard Stereotaxic
Code 51700 Motorized Lab Standard Stereotaxic |
The Motorized Lab Standard Stereotaxic combines the classic design of
our time-proven ‘U’-Frame with customized motors and state-of-the-art
software. Designed to adapt conventional stereotaxic systems, the StereoDrive
software allows motorized, computer controlled stereotaxic positioning in all
3 orthogonal axes. Integrated with Paxinos and Watson’s Rat
Brain in Stereotaxic Coordinates, for either rat or
mouse, the intuitive movement control enables unprecedented accuracy and
higher throughput in all stereotaxic applications. Features: -
Digital Atlas integration -
Frame representation -
Calibration of frame coordinates -
Setting of logical coordinate system (Bregma) -
Coordinates and Atlas visualization of the probe -
Advanced 3D visualization options -
Intuitive probe control Intuitive navigation |
KOPF 900 World most popular Stereotaxic Unit
The Model
900 Small Animal Stereotaxic Instrument originally designed by David Kopf in
1963 is a versatile, easy to use instrument that facilitates proper alignment
of small animals for the Stereotaxic
placement of electrodes, micropipettes and other devices. Code
DKI 900 David Kopf 900 Stereotaxic Unit (100 micron resol.) Code
DKI 960 Dual Arm Stereotaxic Unit (100 micron resol.) Code
DKI 963 Ultra
precise single arm Stereotaxic
Unit (10 micron resolution) Code
DKI 962 Dual Arm
Ultra precise single arm Stereotaxic
Unit (10 micron resol.) Code DKI 926 Mouse
Adaptor Code DKI 970
Neonatal Rat Adaptor Ear Bars available in a wide range of sizes
and tips Probe Holder available in a wide range of
models |
|
|
|
Midgard™ Precision Current Source
The latest generation of the popular precision current source,
designed at M.I.T. for the iontophoresis of neural transport tracers such as horseradish
peroxidase (HRP) or tritiated amino acids into neural tissue, is now
available. It may also be used to make small lesions, and in applications
requiring precise current control through high impedance.
Code 51595
Midgar Lesion Device Code 50880
Silver Wire for electrode making |
|
Model 310 Nanoliter Syringe Pump The 310 reversible
Nano-Pump is used
exclusively with Micro-Syringes. Small size, remote Pump and a rugged
mounting arm make it ideal for use with micromanipulators, stereotaxic units
and other clamping devices. Syringes: from 1 to 100 microliters Minimun Flow : 0,01ul/min Maximum Flow: 26 ml/hour Code 310 Reversible Nano Pump |
|
|
Quintessential Stereotaxic Injector (QSI) New QSI Injector establishes a new standard of versatility and
control. Its unmatched range of volumes and flow rates make it perfect for
research requiring precise injection and/or withdrawal of minute volumes. The
QSI allows progressive visual monitoring of the injection and withdrawal
process. This new injector is ideal for stereotaxic injection allowing the
user to accurately control the volume and flow rate of injections without
wasting precious fluids in excessively long tubing. The fluid goes directly
through a needle on the syringe, mounted directly on the stereotaxic
instrument. Only the Quintessential Stereotaxic Injector enables the researcher
to set volumes as small as 1 picoliter and flow rates from 0.05 nl/min to 520
μl/min. It works with syringes from 0.5ul up to 250μl. Code 53311 Quintessential Stereotaxic Injector (QSI) |
|
|
|
Manual Stereotaxic Injector The
Manual Stereotaxic Injector mounts easily on a Lab Standard, Digital Lab Standard,
or most other stereotaxic instruments. Injection directly through a needle on
the syringe avoids the compliance issues that arise when injections are
forced through plastic tubing. The injector has a universal adaptor for all Hamilton 700, 7000, or
Gas-Tight Series syringes, ranging from 1 to 100 µl sizes, and enables a wide
range of volumes to be delivered. Volumes as small as 200 picoliters may be
infused. Plumber adaptor allows both infusion and withdrawal operation.
Precise withdrawal mechanism makes it simple to pick up even one small
(amount) dose! This results in minimal waste of precious samples and prevents
degradation of samples due to long-term storage of multiple doses in the
syringe at room temperature. With precise manual control, infusions can be as
slow as required; slow infusions are more likely to stay in place, and not
forced back along the needle track, since the neural tissue has more time to
adjust to the incoming fluid. Code 51633 Manual Injector to be
directly mounted on Stereotaxic Units |
|
Code 51222 Manual Injector |
The Manual Injector can delivery fluids
directly through a needle on the syringe avoids the compliance issues that
arise when injections are forced through plastic tubing. The injector has a universal adaptor for
all Hamilton 700, 7000, or Gas-Tight Series syringes, ranging from 1 to 100
µl sizes, and enables a wide range of volumes to be delivered. Volumes as
small as 200 picoliters may be infused. Plumber adaptor allows both infusion
and withdrawal operation. Precise withdrawal mechanism makes it simple to
pick up even one small (amount) dose! This results in minimal waste of
precious samples and prevents degradation of samples due to long-term storage
of multiple doses in the syringe at room temperature. With precise manual
control, infusions can be as slow as required; slow infusions are more likely
to stay in place, and not forced back along the needle track, since the
neural tissue has more time to adjust to the incoming fluid. |
Drills
can be mounted on Stereotaxic Units by suitable holders (51633), Click Here for more information
|
|
THE MOUSE BRAIN IN STEREOTAXIC COORDINATES Paxinos and Franklin The only
stereotaxic atlas in print to depict the mouse brain. It
includes 93 high-quality and accurate coronal sections. Code 45004 |
|
THE RAT BRAIN IN STEREOTAXIC
COORDINATES Paxinos
& Watson, 4th Edition It
includes 46 sections at 5 mm intervals from all 3 cardinal planes, plus 22
spinal cord cross sections. Code 45003 |
via L. Da Vinci 2C - 21023 Besozzo
VA Italy
tel. +39 0332 773210 Fax +39 0332
970141